Product components

Adiabatic Panel “Smart Cooling” components, which ensure 20 – 30% more efficient operation of cooling equipment.

1. BY 70 SS – water-spraying system

Adiabatic (evaporative) panel components, water-spraying systemComponent Description
Micro nozzle panel BY 70 SS is made from the top quality alloy of stainless steel and aluminium. The stainless steel micro nozzle line is deposited in a high resistance anodized aluminium casing, which ensures the longevity and endurance of the component. BY 70 panel casing has been developed to facilitate easy, fast and handy installation and maintenance. Micro nozzle panel BY 70 SS is fixed by special fasteners, which ensures safe and fast attachment of component to the casing of cooling equipment. The unique design ensures that the structure is functional and can be easily installed on any cooling equipment and condenser.
Operation
Micro nozzle panel BY 70 SS facilitates spraying of micro drops (5-20 microns), BY 70 forms a mist wall in front of the condenser of cooling equipment. When the hot air comes into contact with this mist wall, the water mist evaporates and the temperature decreases – this is caused by the transition of a substance from one state of aggregation to another – the water evaporates (an adiabatic process). For further information about the process see the section Products/How it works

Equipment “Smart Cooling™” provides for triple water processing against lime, sterilisation against Legionella bacteria and cleaning from dust, as well as ensures triple condenser protection. For further information read more.

2. BY 70 M – panels with reflective membrane

Component Description
Membrane BY 70 M is made from a polyurethane alloy cell that is deposited in an anodized aluminium casing. The top quality materials ensure the longevity and endurance of component. Due to the unique membrane cell, the installation of membrane on the condenser – fans of cooling equipment does not cause resistance, which is an essential factor in efficiency. Membrane BY 70 M can be easily installed on any cooling equipment and condenser.
Operation
1. Membrane BY 70 M provides the condenser with shading and protects it from direct sunlight.
2. In addition the membrane ensures the cleanliness of condenser and prevents the direct contact with water mist on the exterior condenser.

Equipment “Smart Cooling™” provides for triple water processing against lime, sterilisation against Legionella bacteria and cleaning from dust, as well as ensures triple condenser protection.

3. BBY 70 UV pumping station

Adiabatic (evaporative) panel components, pumping stationComponent Description
The high-pressure station BY 70 UV provides 70-140 bar pressure within the adiabatic panel system. It includes a top quality specially developed high-pressure pump, valves, electronics for the automated operation of system, and a block of UV lamps, which radiates (sterilizes) the water for usage. In order to purify the water from bacteria, including Legionella, a UV block is located in the water preparation station where the radiation – antibacterial sterilisation with UV rays – of water is carried out. The water flow is provided for this UV ray block.
Operation
The high-pressure station ensures that water is delivered to the micro nozzle panel. In order to ensure spraying of micro drops and the formation of mist wall, water supply with high pressure (70-140 bars) is required, which is the primary task of high-pressure station. According to the size of condenser (the size of panels and the number of nozzles), each installation is produced with suitable capacity pumps to provide the required pressure and amount of mist in front of condenser.
Installation performance IP 66. The installation is intended for usage under outdoor conditions.

Equipment “Smart Cooling™” provides triple water processing against lime, sterilisation against Legionella bacteria and cleaning from dust, as well as ensures triple condenser protection.

4. XO100 BIO water treatment system

Adiabatic (evaporative) panel components, BIO water treatment systemComponent Description
BIO container facilitates environment friendly transformation of the structure of lime molecule
Operation
There are BIO tablets for water treatment in the BIO container. The BIO block is intended for changing the lime molecule structure in water. When the water comes into contact with BIO tablets, the lime molecule structure is modified as a result of which the treated liquid does not form lime sediments on the surfaces of cooling equipment. Equipment “Smart Cooling™” provides triple water processing against lime, sterilisation against Legionella bacteria and cleaning from dust, as well as ensures triple condenser protection.

5. BY 30 control Panel, which provides automatic startup of the system at a certain temperature

Adiabatic (evaporative) panel components, control PanelComponent Description
The control panel is made from top quality PE components. It meets IP66 protection category requirements. The control panel regulates the operational processes of the whole system – the Adiabatic Panel “Smart Cooling” – among them initiates its starting and switching off. It can be connected to HVAC BMS management system.
Operation
The control panel activates the operation of the Adiabatic Panel after receiving a signal from sensor of the outdoor air temperature. It means that the system is fully automated. When the air temperature reaches + 22 C, the equipment switches on but, when the temperature falls, it switches off by itself.

6. BY – F fittings

Adiabatic (evaporative) panel components, connective elementsComponent Description
The connective elements and fastenings of the Adiabatic Panel “Smart Cooling” are made from high quality alloys, stainless steel, aluminium and metal. These materials ensure the quality and longevity of connections.
The innovative design of the product (the Adiabatic Panel) “Smart Cooling” has been developed so that it could be assembled quickly and easily as well as dismantled if necessary (out of season). Adiabatic Panels “Smart Cooling™” achieve the best result whichever is possible in the modern energy saving sphere in the field of HVAC.
Countless tests, technical universities’ experiments, trials and customers’ feedback approve the quality and efficiency of “Smart cooling ™” equipment.
To ensure the quality, the production processes at “Smart cooling ™” meet the requirements of ISO quality standards.
The components of “Smart cooling ™”equipment comply with all CE requirements and standards.

  • Technology approved by all leading manufacturers:

    york trane rhoss quay logo_guntner logo_al daikin carrier airwell lennox

  • Contact us:

    Please fill in this form

    Company*

    Name*

    Email*

    Phone

    Your Message

  • Our product brochure

    brochure

    Email *

  • Scientific researches proving efficiency of product

    Here You can read several scientific researches about adiabatic cooling possibilities, obtained results using this effective method.

    Hong Kong Polytechnic University Study on Application of Water Mist Pre-Cooling on Air-Cooled Chillers.
    Download

    Colorado Springs Utilities Whitepaper on Pre-cooling
    Download

  • Look here, how Facebook uses this technology for its data center cooling purposes

  • Our customer reviews and case studies

    global_partnerSchneieder Electric logo

    Products ensured for Lexel factory
    Results: Energy consumption reduced by 31%, cooling capacity raised by 22%
    ROI = 7 month

    Read more…

    global_partner

    PMI-logo

    Products ensured for Philip Morris factory, Intertaba, Italy
    Results: Energy consumption reduced by 37%, cooling capacity raised by 35%
    ROI = 5 month

    Read more…